Stent-induced hypersensitivity leading to refractory in-stent restenosis: a case report

Abstract

Background

Even in the era of new-generation drug-eluting stents, in-stent restenosis remains a common and challenging problem of percutaneous coronary intervention. Among the many factors that contribute to in-stent restenosis, stent-related hypersensitivity is relatively rare, but may be a significant trigger of chronic refractory in-stent restenosis. Nevertheless, it is difficult to diagnose and assess the stent-related hypersensitivity, and there is no standardized treatment strategy.

Case presentation

We present the case of a 63-year-old Chinese female who experienced refractory in-stent restenosis following the successful implantation of platinum chromium everolimus-eluting stents in the left main, left anterior descending and left circumflex artery. Although the cardiovascular risk factors were well-controlled, the patient developed four episodes of acute myocardial infarction with in-stent restenosis within 1 year. Intravascular ultrasound revealed diffuse neointimal hyperplasia in the in-stent restenosis lesion, and the blood tests showed no sign of systemic inflammation or infection. Thus, we speculated that the cause of refractory in-stent restenosis was stent-mediated hypersensitivity. Initially, the in-stent restenosis was treated with paclitaxel-coated balloon angioplasty, and only mild neointimal hyperplasia was observed on intravascular ultrasound 3 months after paclitaxel-coated balloon angioplasty. However, the paclitaxel-coated balloon could not prevent in-stent restenosis recurrence, and she eventually underwent coronary artery bypass grafting. After over 2 years of follow-up, her cardiac function had significantly improved, and the bridging vessels remained patent, as confirmed by computed tomography angiography.

Conclusion

When encountering refractory in-stent restenosis, physicians should consider the potential for stent-associated hypersensitivity. Since there may be difficulty in obtaining histopathological examination of restenotic vessels, intravascular imaging can be instrumental in detecting neointimal hyperplasia and diagnosing stent allergy. Coronary artery bypass grafting may be a reasonable treatment for patients with stent allergy; further clinical research is required to explore the optimal treatments.

Peer Review reports

Introduction

In-stent restenosis (ISR) is a prevailing clinical issue involving multiple underlying etiologies, among which stent-induced hypersensitivity reactions cannot be ignored. Elements of stents, including metal, antiproliferative agents, and copolymer, are known to cause contact allergies [1,2,3], even in the new-generation drug-eluting stents (DES) [4] or biodegradable-polymer stents [5]. Intravascular imaging is often used to guide ISR interventions through revealing the morphology of restenotic neointima and identifying underlying etiologies. Currently, there is no optimal treatment for stent-induced hypersensitivity. Case reports have shown that immunosuppressive drugs, paclitaxel-coated balloon (PCB), bioresorbable vascular scaffolds (BVS), or coronary artery bypass grafting (CABG) can successfully treat recurrent ISR caused by hypersensitivity reactions [1, 4, 5]. Herein, we present a patient with stent-mediated hypersensitivity who experienced four ISR episodes within 1 year and was successfully treated with CABG. Additionally, we noticed that PCB angioplasty could suppress neointimal proliferation for up to 8 months, whereas it could not prevent the recurrence of ISR. Thus, when hypersensitivity is suspected, early CABG may be an appropriate option.

Case report

A 63-year-old Chinese woman with a history of hypertension and type 2 diabetes was admitted to our hospital with acute non-ST segment elevation myocardial infarction (NSTEMI). She had no history of allergies and a family history of cardiovascular disease. Coronary angiography (CAG) showed 80%, 90%, and 60% stenosis in the left anterior descending artery (LAD) (Fig. 1a), left circumflex artery (LCX) (Fig. 2a), and right coronary artery (RCA), respectively. Intravascular ultrasound (IVUS) was performed in the left coronary artery (LCA) and revealed diffuse atherosclerosis, with a minimum lumen area of 2.0 mm2 in proximal LCX (Fig. 4e–h), 3.4 mm2 in the opening of LAD, and 2.0 mm2 in the distal segment of LAD (Fig. 3a–d). We recommended that the patient consider CABG, but she refused. Finally, under guidance using IVUS, four platinum chromium everolimus-eluting stents (PtCr-EES; Promus Premier™, Boston Scientific, Marlborough, MA, USA) of different sizes were implanted into the LCA. In detail, a 2.25 × 28 mm stent was deployed at the middle LAD and a 2.5 × 12 mm balloon (NC Sprinter, Medtronic, USA) was adopted to dilate the lesion at 8–16 atmosphere (atm), a 3.0 × 28 mm stent was implanted into the proximal LAD, and a 3.0 × 12 mm balloon (NC Sprinter, Medtronic, USA) was adopted to dilate the lesion at 12–20 atm (Fig. 1b). Then, one 3.0 × 24 mm stent was deployed at the proximal LCX (Fig. 2b), and one 3.5 × 16 mm was implanted in the left main (LM); simultaneously, the double kissing crush was performed with two non-compliant balloons (3.0 × 12 mm and 4.0 × 9 mm). Finally, the proximal optimization technique was performed in LCA using a 4.0 × 9 mm non-compliant balloon. The images following the first percutaneous coronary intervention (PCI) are shown in Fig. 1b and Fig. 2b. IVUS re-examination demonstrated well-expanded and well-adherent struts, without any edge dissection at LAD (Fig. 3a1-d1) and LCX (Fig. 4e1-h1). Thereafter, she was discharged with optimal medical therapy, including clopidogrel (75 mg/day), aspirin (100 mg/day), and rosuvastatin (10 mg/day).

Fig. 1
figure 1

A series of left anterior descending artery coronary artery angiograms. a Significant left anterior descending artery stenosis before the first percutaneous coronary intervention. b Angiogram following the first percutaneous coronary intervention with three platinum chromium everolimus-eluting stents (a 2.25 × 28 mm and a 3.0 × 28 mm were deployed at the proximal-mid left anterior descending artery, and a 3.5 × 16 mm was implanted in left main). c Angiogram 3 months after the first percutaneous coronary intervention showing in-stent occlusion at middle left anterior descending artery. d Angiogram after the second percutaneous coronary intervention with non-drug-coated balloon. e Angiogram 3 months after the second percutaneous coronary intervention showing severe in-stent restenosis. f Angiogram after the third percutaneous coronary intervention with four paclitaxel-coated balloons (the size of the paclitaxel-coated balloon arranged from the distal left anterior descending artery to left main was 2.5 × 20 mm, 2.75 × 31 mm, 3.0 × 31 mm, and 3.5 × 31 mm, respectively). g Angiogram 4 months after paclitaxel-coated balloon angioplasty showing mild in-stent restenosis. h Angiogram 8 months after paclitaxel-coated balloon angioplasty showing severe in-stent restenosis of left anterior descending artery and left main

Fig. 2
figure 2

A series of left circumflex artery coronary artery angiograms. a Significant stenosis of proximal left circumflex artery before the first percutaneous coronary intervention. b Angiogram after a platinum chromium everolimus-eluting stent 3.0 × 24 mm implantation. c Angiogram 3 months after the first percutaneous coronary intervention showing obvious in-stent restenosis. d Angiogram just after placing a 3.0 × 15 mm paclitaxel-coated balloon to proximal left circumflex artery. e Angiogram 3 months after paclitaxel-coated balloon angioplasty showing no significant in-stent restenosis. f Angiogram 8 months after paclitaxel-coated balloon angioplasty showing severe in-stent restenosis of proximal left circumflex artery and the progressed stenosis of the OM1 and the distal end of the stent. g Angiogram after angioplasty (a 2.5 × 31 mm paclitaxel-coated balloon was placed at proximal left circumflex artery and a 2.5 × 16 mm paclitaxel-coated balloon was placed at OM1). h Angiogram 3 months after paclitaxel-coated balloon angioplasty showing no obvious in-stent restenosis

Fig. 3
figure 3

Coronary angiogram and intravascular ultrasound images of the restenotic lesion of left anterior descending artery and left main. A Angiogram of left anterior descending artery before platinum chromium everolimus-eluting stent implantation. a–d Intravascular ultrasound images of left anterior descending artery before the first percutaneous coronary intervention. (A1) Angiogram of left anterior descending artery after platinum chromium everolimus-eluting stent implantation. a1–d1 Intravascular ultrasound images of left anterior descending artery after the first percutaneous coronary intervention. (A2) Angiogram 6 months after percutaneous coronary intervention showing obvious in-stent restenosis of left anterior descending artery. a2–d2 Intravascular ultrasound images of left anterior descending artery 6 months after first percutaneous coronary intervention showing diffuse low-echoic neointima in the in-stent restenosis lesion, especially in the overlap and opening edge of stent

Fig. 4
figure 4

Coronary angiogram and intravascular ultrasound images of the restenotic lesion of left circumflex artery. B Pre-stent placement coronary angiogram of left circumflex artery. e–h Intravascular ultrasound images of left circumflex artery before the first percutaneous coronary intervention. (B1) Post-stent placement coronary angiogram of left circumflex artery. (e1–h1) Intravascular ultrasound images of left circumflex artery after the first percutaneous coronary intervention. (B2) Angiogram 3 months after the in-stent restenosis was treated with paclitaxel-coated balloon showing no obvious in-stent restenosis in left circumflex artery. (e2–h2) A total of 3 months after the in-stent restenosis of left circumflex artery was treated with paclitaxel-coated balloon; intravascular ultrasound images showing mild intimal hyperplasia inside the stent. Whereas, on intravascular ultrasound, significant progression of the lesion was observed at the edge and distal end of the stent

A total of 3 months later, the patient developed NSTEMI and the electrocardiogram showed significant ST-segment elevation of V1 to V5. The transthoracic echocardiography (TTE) revealed that left ventricular ejection fraction (LVEF) decreased from a preoperative 65% to 43%, and left ventricular internal diameter at end-diastole (LVIDd) increased from a preoperative 4.7 cm to 4.9 cm. Simultaneously, the low-density lipoprotein cholesterol (LDL-C) increased from thet preoperative 1.24 mmol/L to 1.99 mmol/L, and glycosylated hemoglobin decreased from the preoperative 8.7% to 7.6%. Emergent CAG showed occlusive restenosis in the middle LAD (Fig. 1c) and diffuse ISR in the proximal LCX (Fig. 2c). The ISR in the LCX was successfully treated with a PCB (SeQuent® Please NEO, B. Braun, Melsungen, Germany) and thrombolysis in myocardial infarction (TIMI) III flow was obtained. In addition, the LAD restored TIMI II flow after non-drug-coated balloon angioplasty. Postoperative treatment with evolocumab and sacubitril/valsartan was initiated; subsequently, the patient was discharged with ticagrelor to replace clopidogrel.

Nevertheless, 3 months later, she developed NSTEMI again caused by ISR of LAD (Fig. 1e), despite her LDL-C level being even lower at 0.73 mmol/L. We considered using optical coherence tomography to evaluate the ISR lesion, however, limited by the conditions of her medical insurance, we ultimately chose IVUS as the alternative modality. IVUS revealed diffuse heterogeneous low-echoic neointima in the ISR lesion and distal end of the stent, especially at the stent edges and overlaps, with no evidence of thrombus, dissection, or stent fracture (Fig. 3a2–d2 and Fig. 4e2–h2). Interestingly, in the LCX, IVUS showed low-echoic proliferative tissue outside the stent, but not inside the stent (Fig. 4e2–h2). The patient had excellent medication adherence. A platelet aggregation test demonstrated a good response to antiplatelet drugs. Thromboelastogram test results and levels of protein C, protein S, and antithrombin were normal, effectively ruling out thrombophilia. Laboratory tests revealed low levels of C-reactive protein (2.14 mg/L), erythrocyte sedimentation rate (18 mm/h), and interleukin-6 (2.04 pg/mL). Serologic work-up showed negative results for a comprehensive panel of autoimmune antibodies, including antinuclear, anti-dsDNA, antiphospholipid, anti-neutrophil cytoplasmic, and anti-thyroid peroxidase antibodies, among others. Given the recurrent and aggressive restenosis with diffuse neointimal hyperplasia, a stent-allergy reaction was suspected. Owing to the refusal of CABG, PCB (Lepu Medical, Beijing, China) angioplasty was eventually carried out from the distal LAD to LM. Postoperatively, we suggested oral anti-inflammatory therapy with glucocorticoids, but the patient refused.

A total of 4 months later, she was readmitted and diagnosed with NSTEMI. The fourth CAG revealed severe stenosis of the first obtuse marginal (OM1) and significant ISR of proximal LCX (Fig. 2f), which were both treated with PCB (Lepu Medical, Beijing, China). Unsurprisingly, she experienced the fourth ISR 3 months later. The CAG documented 90% ISR of the proximal LM and 70–95% ISR of the proximal LAD (Fig. 1h). Finally, she underwent CABG surgery and recovered very well. The TTE revealed that LVIDd decreased from the preoperative 54 mm to 45 mm, and LVEF increased from the preoperative 52% to 55%. The patient was followed up for over 2 years. She remained asymptomatic and there was no stenosis in bridging vessels on computed tomography angiography. The timeline and characteristics of this case are summarized in Table 1.

Table 1 Summary of patient characteristics

Discussion

With the application of the new-generation DES, the incidence of ISR has been reduced to 5–10% [6]. However, ISR remains a critical concern owing to its potential to cause severe complications, such as STEMI [7]. There are multiple factors may contribute to DES restenosis, including mechanical, biological, genetic, and technical factors [6]. In terms of biological factors, in addition to antiplatelet drug resistance, hypersensitivity to the stent components may promote inflammation progression and trigger ISR. In this case, refractory ISR appeared in the short term, despite well-controlled hyperlipidemia and diabetes. There were no identifiable genetic or procedural risk factors. The IVUS imaging indicated that peri-stent tissue appeared to consist of excessive neointimal hyperplasia without thrombotic components. Therefore, we suggested that refractory ISR was due to allergic inflammation caused by the stent. However, the patient declined to undergo a patch test, and a definitive diagnosis requires histopathological examination.

Numerous reports have documented hypersensitivity reactions following stent implantation, particularly with bare metal stents and first-generation DES, which are made of 316 L stainless steel containing nickel, chromium, and molybdenum [8]. In particular, nickel is considered the most potent allergen [9] and may lead to recurrent ISR [8]. The PtCr-EES implanted in this patient is a new-generation DES that contains little nickel (9%) and uses a platinum-chromium alloy as the scaffold. The PtCr-EES also contains the antiproliferator everolimus and biocompatible fluorinated copolymer. With high biocompatibility, the fluorinated copolymer can inhibit platelet aggregation, reduce inflammation, and potentially prevent allergic reaction [10]. However, there have been reports of hypersensitivity vasculitis associated with poly n-butyl methacrylate, a component of the polymer [2]. As an immunosuppressive agent, everolimus can be released approximately 100% from polymer within 4 months after implantation in vivo and can suppress allergic reaction [11]. In this case, recurrent ISR occurred after the complete release of everolimus, suggesting that the polymer or metal components of the stent were more likely responsible for the allergic reaction and ISR.

The optimal treatment for this condition is still unclear. Although the most effective therapy of ISR is repeated DES implantation, it should be discarded in patients with stent-associated hypersensitivity reaction. To reduce the occurrence of stent allergy, some researchers have proposed using nickel-free stainless steel materials and bioresorbable metal stents. Polymer-free DES have also been evaluated in clinical studies and demonstrated no significant difference compared with permanent-polymer DES [12, 13]. Recently, a study suggested using titanium alloy as a drug reservoir layer instead of polymer coatings to create nickel- and polymer-free stents [14]. In addition, BVS have also received increasing attention. For example, absorbable magnesium alloy stents have demonstrated antithrombotic properties in short-term clinical trials; however, long-term follow-up data are required [15]. A case reported that the ISR cycle was interrupted by PCI with PCB and BVS, combined with oral low-dose steroids [4]. However, BVS have also been reported to cause an allergic reaction and ISR [5, 16], which was successfully treated with CABG [5]. Regarding PCB, IVUS imaging of this patient 3 months after PCB angioplasty revealed that PCB effectively reduced neointimal hyperplasia. Unfortunately, critical ISR recurred 8 months later, indicating that PCB alone could not terminate the ISR cycle caused by allergic inflammation. In terms of pharmacological therapy, oral immunosuppressants may inhibit the recurrence of ISR. For instance, prednisolone and tranilast have been reported to prevent ISR attributed to hypersensitivity reaction [1]. Other drugs may also have anti-inflammatory and anti-atherosclerotic functions, such as sodium cromoglycate and leukotriene receptor antagonists [8]. Finally, as reported in this case, CABG may be a reasonable treatment strategy. It is worth mentioning that the majority of surgical staples contain little amounts of nickel and may lead to aggressive coronary artery stenosis [4]. Thus, materials containing nickel should be avoided in CABG procedures.

Conclusion

When refractory ISR occurs, physicians should remain vigilant for the possibility of stent-related hypersensitivity reactions. Although PCB angioplasty can suppress neointimal proliferation, it is insufficient to prevent the recurrence of ISR. In cases where stent-related hypersensitivity is suspected, CABG may be an optimal treatment option.

Availability of data and materials

The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding author.

Abbreviations

ISR:

In-stent restenosis

DES:

Drug-eluting stents

PCB:

Paclitaxel-coated balloon

BVS:

Bioresorbable vascular scaffold

CABG:

Coronary artery bypass grafting

NSTEMI:

Non-ST segment elevation myocardial infarction

CAG:

Coronary angiography

LAD:

Left anterior descending artery

LCX:

Left circumflex artery

RCA:

Right coronary artery

IVUS:

Intravascular ultrasound

LCA:

Left coronary artery

IVUS:

Rransthoracic echocardiography

LVEF:

Left ventricular ejection fraction

LVIDd:

Left ventricular internal diameter at end-diastole

LDL-C:

Low-density lipoprotein cholesterol

TIMI:

Thrombolysis in myocardial infarction

References

  1. Nakajima Y, Itoh T, Morino Y. Metal allergy to everolimus-eluting cobalt chromium stents confirmed by positive skin testing as a cause of recurrent multivessel in-stent restenosis. Catheter Cardiovasc Interv. 2016;87(4):E137-142.

    Article  PubMed  Google Scholar 

  2. Otsuka F, Yahagi K, Ladich E, et al. Hypersensitivity reaction in the US Food and Drug Administration-approved second-generation drug-eluting stents: histopathological assessment with ex vivo optical coherence tomography. Circulation. 2015;131(3):322–4.

    Article  PubMed  Google Scholar 

  3. Wheatcroft S, Byrne J, Thomas M, et al. Life-threatening coronary artery spasm following sirolimus-eluting stent deployment. J Am Coll Cardiol. 2006;47(9):1911–2.

    Article  PubMed  Google Scholar 

  4. Jurado-Roman A, Lopez-Lluva MT, Sanchez-Perez I, et al. Bioresorbable vascular scaffold to treat malignant in-stent restenosis in a patient with nickel allergy. Cardiovasc Revasc Med. 2017;18(6S1):38–40.

    Article  PubMed  Google Scholar 

  5. Jimba T, Hashikata T, Matsushita M, et al. Repetitive restenosis in a biodegradable polymer sirolimus-eluting stent with hypersensitivity reaction: a case report. Eur Heart J Case Rep. 2020;4(1):1–5.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Aoki J, Tanabe K. Mechanisms of drug-eluting stent restenosis. Cardiovasc Interv Ther. 2021;36(1):23–9.

    Article  PubMed  Google Scholar 

  7. Moussa ID, Mohananey D, Saucedo J, et al. Trends and outcomes of restenosis after coronary stent implantation in the United States. J Am Coll Cardiol. 2020;76(13):1521–31.

    Article  PubMed  Google Scholar 

  8. Hu W, Jiang J. Hypersensitivity and in-stent restenosis in coronary stent materials. Front Bioeng Biotechnol. 2022;10:1003322.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Basko-Plluska JL, Thyssen JP, Schalock PC. Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis. 2011;22(2):65–79.

    Article  PubMed  Google Scholar 

  10. Torii S, Jinnouchi H, Sakamoto A, et al. Drug-eluting coronary stents: insights from preclinical and pathology studies. Nat Rev Cardiol. 2020;17(1):37–51.

    Article  CAS  PubMed  Google Scholar 

  11. Bennett J, Dubois C. A novel platinum chromium everolimus-eluting stent for the treatment of coronary artery disease. Biologics. 2013;7:149–59.

    CAS  PubMed  PubMed Central  Google Scholar 

  12. van Hemert ND, Voskuil M, Rozemeijer R, et al. 3-year clinical outcomes after implantation of permanent-polymer versus polymer-free stent: ReCre8 landmark analysis. JACC Cardiovasc Interv. 2021;14(22):2477–86.

    Article  PubMed  Google Scholar 

  13. Kufner S, Ernst M, Cassese S, et al. 10-Year outcomes from a randomized trial of polymer-free versus durable polymer drug-eluting coronary stents. J Am Coll Cardiol. 2020;76(2):146–58.

    Article  CAS  PubMed  Google Scholar 

  14. Soliman AM, Tolba SA, Sharafeldin IM, et al. Ni-free, built-in nanotubular drug eluting stents: experimental and theoretical insights. Mater Sci Eng C Mater Biol Appl. 2019;103:109750.

    Article  CAS  PubMed  Google Scholar 

  15. Sakamoto A, Jinnouchi H, Torii S, et al. Understanding the impact of stent and scaffold material and strut design on coronary artery thrombosis from the basic and clinical points of view. Bioengineering. 2018;5(3):71.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  16. Yamamoto H, Yoshida N, Kondo T, et al. In-stent restenosis due to delayed healing of abluminal bioresorbable polymer everolimus-eluting stent: insight from histopathological evaluation with directional coronary atherectomy. Eur Heart J Case Rep. 2021;5(9):ytab370.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

We thank our hospital staff, who helped us with the care of this patient.

Funding

This work was supported by the Yunnan Provincial Clinical Medicine Research Special Program (no. 202405AJ310003), Hospital-Level Research Project of Fuwai Yunnan Hospital, Chinese Academy of Medical Sciences (no. 2025YFKT-QN-03), and Yunnan Province Science and Technology Department & Kunming Medical University Joint Special Fund for Applied Basic Research (no. 202301AY070001-042).

Author information

Authors and Affiliations

Authors

Contributions

MM participated in this patient’s management and follow-up, collated clinical examination results and diagrams, and wrote the manuscript. JT assessed the patient, performed the procedure, revised the manuscript, and gave final approval of the manuscript.

Corresponding author

Correspondence to Jiong Tang.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Competing interests

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ma, M., Tang, J. Stent-induced hypersensitivity leading to refractory in-stent restenosis: a case report. J Med Case Reports 19, 96 (2025). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13256-025-05122-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s13256-025-05122-4

Keywords